Send inquiry
Model Number: ZKJ-GT50KW
Brand Name: ZONHAN
Key Specifications/Special Features:
ZKJ-GT (Grid-tie) model product characteristics:◆The product is manufactured according the JB/T6939.1-2004 industrial standard and GB/T 19115.1-2003 national standard also with users’ technical requirements.◆Two sets of control systems: PWM constant voltage system and three-phase dump load system.◆PWM constant voltage control is 120% of the rated power of the wind turbine. In case exceeding of PWM’s capacity, the three-phase dump load will automatically start immediately. After 10-20 minutes, the three-phase dump load will stop and the wind turbine will re-start to resume power supply to ensure the safe running of the overall wind turbine generation system.◆Under the strong or super-strong wind conditions, the controller can conduct constant voltage output to ensure the inverter safety running.◆Under the condition of disconnected grid-connected inverter, the controller can conduct constant voltage output and wait for inverter resumption.◆The three-phase dump load of the controller will automatically start and the inverter will stop grid output when the power grid is off. As soon as the grid power resuming, the controller stops three-phase dump load and the inverter will resume power supply.◆For the different wind turbine generator type, the controller can be equipped with mechanical yawing, furled empennage, mechanical or hydraulic, pneumatic, electric magnetic and other brake functions.
Type
50klW
100kW
Wind turbine rated power
50kW
100kW
Wind turbine Max. power
100kW
200kW
Function
Rectifier, control
Display mode
LCD
Display content
Wind turbine voltage, wind turbine current, wind turbine power, DC output voltage,
DC output current, DC output power
PWM constant voltage
≥650dc
≥650dc
Wind turbine 3-phase dump load voltage1
670±5Vdc
670±5Vdc
Three-phase dump load 1 delay time
12-20 min
12-20 min
Wind turbine 3-phase dump load voltage2
680±5Vdc
680±5Vdc
Three-phase dump load 2 delay time
12-20 min
12-20 min
Wind turbine 3-phase dump load voltage3
700±5Vdc
700±5Vdc
Three-phase dump load 3 delay time
12-20 min
12-20 min
Low-voltage
≤200Vdc
≤200Vdc
PWM dump load fuse
63A
100A
Fuse of DC output
100A
200A
Self-provided connecting wire of the PWM dump load (mm)
>10mm
>20mm
Self-provided connecting wire of the dump load 1(mm)
>10mm
>16mm
Self-provided connecting wire of the dump load 2(mm)
>10mm
>16mm
Self-provided connecting wire of the dump load 3(mm)
>10mm
>16mm
Work environment temperature
-30-60°C
Relative humidity
<90% No condensation
Noise (1m)
<40dB
Degree of protection
IP20 (Indoor)
Cooling method
Forced air cooling
*Communication interface (optional)
RS485/USB/GPRS/Ethernet
*Temperature compensation(optional)
-4mv/°C/2V,-35°C~+80°C,
Accuracy:±1°C
Size of the controller (mm)
690*590*1300 mm
690*590*1300 mm
Weight of the controller
120Kg
120Kg
Size of the dump load (mm)
760*520*1200(3pcs)
760*520*1200(4pcs)
Weight of the dump load
330Kg
440Kg
DC output current, DC output power
Accuracy:±1°C
Shipping Information:
- FOB Port: Shanghai
- Lead Time: 5 - 10 days
- HTS Code: 8543.70.99 90
- Dimensions per Unit: 69 × 59 × 130 Centimeters
- Weight per Unit: 120 Kilograms
- Units per Export Carton: 1
- Export Carton Dimensions L/W/H: 75 × 65 × 135 Centimeters
- Export Carton Weight: 128 Kilograms
Main Export Markets:
- Central/South America
- North America
- Western Europe